INVESTIGATION OF POWER SUPPLY PARAMETER EFFECT ON PERFORMANCE OF VIBRATOR METER WITH MAGNETIC ACTUATOR
Abstract and keywords
Abstract (English):
The work objective is to study dosing accuracy changes of the vibration measurer with an electromagnetic drive powered by the industrial network. The previously obtained dependences of the vibration measurer performance on the vibration frequency, ampli-tude and direction of the magnetic actuator, and on the properties of the dispensed material are used. These relationships are obtained at the pilot plant with the stabilized power settings. It is found that the supply from the vibration agitator of the industrial network significantly (up to 5%) affects the vibrator meter performance deviation from the given one that may become unacceptable when dispensing the ingredients requiring higher accuracy. To eliminate uncontrolled deviations of the dispenser performance from the stochastic variations of voltage and frequency, a voltage- and fre-quency-stabilized supply of the vibration activator electromagnet should be used.

Keywords:
dispensing, vibration measurer, magnetic actuator, power network, metering accuracy.
Text

Результаты расчета убытков, причиняемых ежегодно экономике США перерывами в подаче напряжения и отклонениями параметров качества электроэнергии, показали, что экономика страны теряет от 104 до

164 млрд долларов. Если допустить, что ущерб от качества электроэнергии в России примерно такой же, то теорети-чески можно предположить потери порядка 37 млрд долларов ежегодно (по уровню цен 2012 г) [1, 2]. Весьма значи-телен ущерб от нарушения качества электроснабжения особенно в отраслях непрерывного цикла. К таким производ-ствам относится и комбикормовая промышленность с процессом дозирования тонких ингредиентов.

Изменение напряжения (разнопеременное, одиночное, быстрое, случайное прерывание, провал и перенапряжение), частоты напряжения влияют на привод дозатора, что ведет к нарушению точности дозирования и качества комбикормов иногда до недопустимых пределов. Поэтому исследование влияния качества электропитания вибрационного доза-тора является весьма актуальным.

В работах [3, 4] представлены результаты исследований вибрационного дозатора. Вибрационный дозатор со-стоял из вибрационного лотка и бункера, которые имели гибкую связь между собой и подвергались вибрационному воздействию от единого источника колебаний. Источником колебаний был электромагнит, питание которого осу-ществлялось от генератора низкочастотных колебаний. Тяговая сила электромагнита зависела от величины тока в об-мотке и частоты питающего напряжения. Дозатор находился в цехе при постоянных значениях температуры и влаж-ности и дозировал модельный материал. На рис. 1 представлено отклонение производительности дозатора от среднего значения в зависимости от времени суток при непрерывной работе.

References

1. Denisov, V.I., Dzyuba, A.A. Osnovy rynochnykh otnosheniy v elektroenergetike. [Basics of market relations in the power industry.] Power Technology and Engineering, 2003, no. 8, pp. 13–18 (in Russian).

2. Brovkina, Y. Kak mnogo teryaet ekonomika na kachestve elektroenergii? [How much does economy lose on pow-er quality?] EnergoRynok, 2013, no. 10, pp. 37–39 (in Russian).

3. Tupolskikh, T.I. Proizvoditel´nost´ vibratsionnogo lotka dozatora i parametry vibrirovaniya. [Performance of dis-penser vibrating chute and vibration parameters.] Don State Technical University, Rostov-on-Don, 2000, 6 p.; VINITI, Russ.Dep., 09.02.00 №300-В00 (in Russian).

4. Tupolskikh, T.I., Ilchenko, V.D. Issledovanie tekhnologicheskogo protsessa raboty vibratsionnogo pitatelya s bun-kerom. [Study on the process of the vibration hopper-feeder operation.] Vestnik of DSTU, 2001, vol. 1, no. 3(9), pp. 56–65 (in Russian).

5. Mezhdunarodnye standarty i otsenka sootvetstviya dlya vsekh elektricheskikh, elektronnykh i smezhnykh tekhnologiy. [International Standards and Conformity Assessment for all electrical, electronic and related technologies.] Inter-national Energy Commission. Available at: http://www.iec.ch/dyn/www/f (accessed: 07.11.2015) (in Russian).

6. GOST R 50571–4–44–2011 (MEK 60364–4–442007). Elektroustanovki nizkovol´tnye. Chast´ 4–44. Trebovaniya po obespecheniyu bezopasnosti. Zashchita ot otkloneniy napryazheniya i elektromagnitnykh pomekh. — Vved. 2012–07–01. [GOST R 50571-4-44-2011 (MEK 60364-4-442007). Low-voltage electrical installations. Part 4-44. Safety requirements. Protection against voltage disturbances and electromagnetic disturbances. Intr. 2012–07–01.] Moscow: Standartinform, 2012, 48 p. (in Russian).

7. Allan C. Breller. Global Quality Manager and Six Sigma Champion. EKC Technology DuPont Electronics and Communications. 2520 BarringtonCourtHayward, CA 94545.

8. Electric current abroad. U.S. Department of Commerce International Trade Administration, February 2002.

9. GOST 32144-2013. Elektricheskaya energiya. Sovmestimost´ tekhnicheskikh sredstv elektromagnitnaya. Normy kachestva elektricheskoy energii v sistemakh elektrosnabzheniya obshchego naznacheniya. — Vved. 2014–07–01. [GOST 32144-2013. Electric energy. Electromagnetic compatibility of technical equipment. Power quality limits in the public pow-er supply systems. Intr. 2014–07–01.] Moscow: Standartinform, 2014, 19 p. (in Russian).

10. Operativnaya rabota v elektroenergetike. [Operational work in the power industry.] Power dispatcher. Available at: http://www.operby.com (accessed: 09.11.2015) (in Russian).

11. Guter, R.S., Ovchinskiy, B.V. Elementy chislennogo analiza i matematicheskoy obrabotki rezul´tatov opyta. [Ele-ments of numerical analysis and mathematical processing of the experimental results.]Moscow: Fizmatgiz, 1962, 356 p. (in Russian).